What do Danfoss ERC, EKC, and Optyma Plus alarm codes mean?

What these controllers do, and when the codes show up

Danfoss electronic controllers run an enormous share of commercial refrigeration, and several of its families end up on walk-in coolers and their condensing units: the ERC 211/213/214 controllers found on cabinets and walk-in control panels, the EKC 202 and AK-CC 210 case and room controllers, and the Optyma Plus controller mounted on Danfoss condensing units that serve walk-ins. The code language is consistent across them: E-codes are sensor and electronics errors (E29 is the air sensor, E27 the defrost sensor), A-codes are alarms — temperature (A01/A02 or A1/A2), door (A04/A4), voltage protection (A99/AA1), and the condenser pair worth memorizing: A61 warns the condenser is running hot, A80 is the blocked-condenser lockout that requires a manual reset after you clean the coil.

Some AK-CC models add HACCP logging (A60) that timestamps food-safety excursions. Find your controller family and exact code below for the documented meaning, the safe checks, and when it's a service call.

Code pages

Which Danfoss controller do you have?

Controller Alarm codes coveredPage
Danfoss ERC 211 / 213 / 214
Danfoss ERC 21X display; E27/E29/E30 sensor errors and A01–A99 alarms.
12 alarm codes: E29, E27, E30, A01, A02, A99, AA1, A61, A80, A04 and 2 moreFull list →
Danfoss EKC 202 / AK-CC 210
Danfoss case and cold-room controller; E, A and S (status) codes.
16 alarm codes: A1, A2, A4, A5, A15, A45, A59, E1, E6, E27 and 6 moreFull list →
Danfoss Optyma Plus
Controller built into a Danfoss condensing unit; A2, A17, A80, A96.
16 alarm codes: A2, A11, A16, A17, A45, A80, A96, A97, A98, E1 and 6 moreFull list →

Not sure yet what the controller is actually measuring when it throws one of these? What do the alarm codes on my walk-in cooler mean? explains the refrigeration behind every code on this site — sensors, superheat, defrost and the condenser — once, in one place.

Danfoss ERC 211 / 213 / 214

The Danfoss ERC 211, 213, and 214 are compact electronic refrigeration controllers fitted by many commercial cabinet and refrigeration equipment makers, and they turn up on walk-in panels as well as reach-ins and display cases. The display normally shows temperature; faults appear as E-codes for failed sensors (E27 defrost, E29 air, E30 condenser) and A-codes for alarm conditions — temperature, voltage, condenser, and door alarms. One code worth knowing before you panic: A45 means the unit was switched to standby on purpose via its main-switch parameter, not that anything broke. Practical tip: A80 (condenser blocked) is manual-reset — clean the coil first, then power-cycle, or it just comes straight back.

All 12 Danfoss ERC 211 / 213 / 214 codes — meanings, checks, diagnosis and parts →

Danfoss EKC 202 / AK-CC 210

The Danfoss EKC 202 and its successor the AK-CC 210 are panel-mount case controllers used across commercial refrigeration — display cases, cold rooms, and walk-in evaporator control, often tied into a store's front-end monitoring network. Faults show as short codes plus a plain-text line on the display: E-codes are defects (E1 controller fault, E27 and E29 sensor errors) and A-codes are alarms (A1 high temperature, A2 low, A4 door, A45 standby). Practical tip: A45 standby doesn't trip the alarm relay on the AK-CC 210 — a box someone left in standby can sit warming quietly, so treat an unexplained 'Standby mode' display as urgent, not informational.

The Danfoss AK-CC 210 is a case controller for commercial refrigeration — cold rooms, display cases, and walk-in evaporator sections, frequently networked into a central monitoring system that logs its alarms. It reports with the same short-code convention as the rest of Danfoss's EKC/AK line: E-codes for sensor and hardware defects (E25 and E26 are the S3 and S4 air sensors) and A-codes for alarm conditions, including A60, a dedicated HACCP high-temperature alarm for food-safety monitoring. Practical tip: when A60 shows, log the actual product temperature immediately — that alarm is a compliance record as much as an equipment warning, and your notes matter at inspection time.

All 30 Danfoss EKC 202 / AK-CC 210 codes — meanings, checks, diagnosis and parts →

Danfoss Optyma Plus

Danfoss Optyma Plus condensing units — the outdoor or machine-room half of many walk-in cooler and freezer installations — carry their own built-in electronic controller with a small display on the unit. It reports faults as short codes: A-codes for alarms (A2 low suction pressure, A17 pressure safety trip, A80 condenser airflow, A96 discharge temperature) and E-codes for controller defects. Because this controller lives on the condensing unit, its alarms lean toward compressor protection — pressure trips and overheating — rather than box temperature. Practical tip: when one of these codes stops the compressor, resist the urge to keep resetting; the protections exist because forcing restarts is how compressors get destroyed.

All 16 Danfoss Optyma Plus codes — meanings, checks, diagnosis and parts →

Every Danfoss code, by controller

Danfoss ERC 211 / 213 / 214:

Danfoss EKC 202 / AK-CC 210:

Danfoss Optyma Plus:

Related guides

A code is the controller's report of a box problem. These three guides cover a walk-in that is not cooling, the daily and weekly maintenance checks, and ice building up in the box. Walk-in cooler showing an alarm code? lists every brand if this is not the controller on the display.

The rest of the symptom guides are on the walk-in cooler guides page.

Common questions

Which Danfoss controllers end up on walk-ins?

The ERC 211, 213, and 214 on cabinets and walk-in control panels, the EKC 202 and AK-CC 210 case and room controllers, and the Optyma Plus controller mounted on Danfoss condensing units that serve walk-ins.

What is the difference between a Danfoss E-code and an A-code?

E-codes are sensor and electronics errors. E29 is the air sensor and E27 is the defrost sensor. A-codes are alarms: temperature (A01/A02 or A1/A2), door (A04/A4), and voltage protection (A99/AA1).

What do Danfoss A61 and A80 mean?

A61 warns that the condenser is running hot. A80 is the blocked-condenser lockout, and it requires a manual reset after the coil is cleaned.

What is Danfoss alarm A60?

Some AK-CC models add HACCP logging. A60 timestamps a food-safety temperature excursion.